This website requires cookies to provide all of it's features. Please enable your browser cookies.

Wafer Type Double Check Valve

Wafer Type Double Check Valve

1、You are in restricted area and need password. Please Contact us to obtain documents.

2、PasswordIf you have any questions about quotation or cooperation, please feel free to send us inquiry. Inquiry us

Brochure:
Manual: Download
3D step: Download
Certificates: Download
Quote
1.Specification
Size: 2"-36"
Pressure: 150LB-2500LB
Body Material: WCB, WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, Monel, 20# Alloys, 4A, 5A, C95800, C95500, A105, F304, F304L, F316, F316L, LF1, LF2, LF3, LF9, F51, F53, F11, F22, etc.
Seal Material: STELLITE, 13Cr, SS304, SS316, etc.
Connection Type: Wafer
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Design and Manufacture: API 594
Test Standard: API 598,API 6FA, ISO 15848-1-2
2.Features

Dual plate type with spring loaded

Available with metal-to-metal seat and soft seat, renewable seat and integral seat

Horizontal or vertical installation are both applicable.

Short structural length, small volume

Automatically opened and closed by the force generated by the flow of the medium itself in the pipeline

3.FAQ
What is a double check valve

A double check valve is a type of backflow prevention device that is used to protect potable water supplies from contamination. It consists of two independently acting check valves that are assembled in series. The first check valve prevents backflow from the system into the potable water supply, while the second check valve provides a backup protection in case the first check valve fails. The double check valve is typically used in low hazard applications, such as irrigation systems, fire sprinkler systems, and boiler feed water systems. It is important to note that double check valves require periodic testing and maintenance to ensure proper operation and prevent contamination of the potable water supply. api 6d ball valve

How does a double check valve work

A double check valve works by using two independently acting check valves to prevent backflow and protect potable water supplies from contamination.

When water flows in the forward direction, the first check valve opens, allowing water to pass through. The second check valve remains closed in this direction. This ensures that water can flow freely from the supply to the system being protected. forged ball valve

However, if there is a reversal of flow or backpressure, the first check valve closes to prevent water from flowing back into the potable water supply. At the same time, the second check valve opens to provide a backup protection. This double barrier of check valves ensures that even if one check valve fails, the second one will prevent any backflow from occurring.

The double check valve is typically used in low hazard applications where there is a risk of non-potable water or contaminants entering the potable water supply. It is important to note that double check valves require periodic testing and maintenance to ensure proper operation and prevent contamination. carbon steel gate valves

What is a double check valve used for

A double check valve is a type of backflow prevention device that is used to protect potable water supplies from contamination. It is typically installed in commercial and industrial applications where there is a risk of backflow, such as in irrigation systems, fire sprinkler systems, and boiler systems.

The double check valve works by using two check valves that are installed in series. The first check valve prevents backflow from the downstream system into the potable water supply, while the second check valve provides an additional layer of protection in case the first check valve fails. high temperature gate valves

If the pressure in the downstream system exceeds the pressure in the potable water supply, the first check valve will close and prevent backflow. If the first check valve fails, the second check valve will provide backup protection and prevent backflow from occurring.

Double check valves are designed to be easy to install and maintain, and they are typically less expensive than other types of backflow prevention devices. However, they are not suitable for all applications and may not provide adequate protection in certain situations. It is important to consult with a qualified engineer or plumbing professional to determine the appropriate type of backflow prevention device for your specific application, duplex stainless steel ball valve.

Does a double check valve reduced flow

A double check valve does not typically reduce flow significantly. It is designed to provide backflow prevention by having two check valves in series. This design allows for increased reliability and protection against backflow. However, it is important to note that any valve, including a double check valve, will introduce some resistance to flow due to its design and construction. This resistance is typically minimal and should not significantly impact the overall flow rate.

Can a double check valve be installed underground

Yes, a double check valve can be installed underground. Double check valves are commonly used in plumbing systems to prevent backflow and ensure the safety of potable water. They are designed to be installed in a horizontal position, but they can also be installed vertically or underground, depending on the specific requirements of the installation, fugitive emission gate valve.

When installing a double check valve underground, it is important to consider accessibility for maintenance and inspection purposes. Access points or manholes should be provided to allow for easy access to the valve for testing, repair, or replacement.

Additionally, proper protection should be provided to prevent damage to the valve from external factors such as soil movement, water pressure, or freezing temperatures. This may include using protective enclosures or burying the valve in a protective casing.

It is recommended to consult with a professional plumber or follow the manufacturer's guidelines and local plumbing codes when installing a double check valve underground to ensure proper installation and compliance with regulations.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details

Related Products

×

Contact Us To Download File

Get in Touch

×