1、You are in restricted area and need password. Please Contact us to obtain documents.
2、PasswordIf you have any questions about quotation or cooperation, please feel free to send us inquiry. Inquiry us
Size: | 2"-36" |
Pressure: | 150LB-2500LB |
Body Material: | CF8, CF8M, CF3, CF3M, CD3MNWCuN, CW2M, Monel, CN7M, 20#Alloys, 4A, 5A, etc. |
Seal Material: | PTFE, METAL SEAT |
Connection Type: | Flanged, Butt Welded, Socket Welded, NPT |
Operation: | Handwheel, gear operated, pneumatic, motorized |
Face to Face Dimension: | ASME B16.10 |
Flange End Dimension: | ASME B16.5 |
Butt Welded Dimension: | ASME B16.25 |
Design and Manufacture: | API 6D |
Test Standard: | API 598, API 607, API 6FA, ISO 15848-1-2 |
Available with material CF3, CF8, CF3M, CF8M, CF8C, CN7M, CD4MCU, etc.
Bolted bonnet, bidirectional seal, fire safe.
Suitable temperature range: -29~550 ℃.
It can be used to regulate the flow of liquids containing suspended solids, for example, slurry.
Used for strong corrosion, high salinity, high temperature, and other special or severe working conditions.
It can be used for frequent operation, quick and convenient to open and close.
The installation of plug valves can vary depending on the specific type and application, but here are some general steps to follow:
1. Prepare the pipeline: Before installing the valve, make sure the pipeline is clean and free of debris. Check the pipeline for any damage or defects that could affect the valve's performance.
2. Position the valve: Position the valve in the pipeline and make sure it is aligned properly. Use a level to ensure the valve is installed in a horizontal position.
3. Connect the valve: Connect the valve to the pipeline using the appropriate fittings and gaskets. Tighten the bolts evenly to ensure a proper seal.
4. Test the valve: Test the valve to ensure it is functioning properly. Open and close the valve several times to check for any leaks or other issues.
5. Secure the valve: Once the valve is installed and tested, secure it in place using the appropriate brackets or supports.
6. Document the installation: Keep a record of the valve's installation, including the date, location, and any other relevant information.
It is important to follow the manufacturer's instructions and any applicable industry standards when installing plug valves to ensure they are installed correctly and operate safely and efficiently.
Plug valves are suitable for a wide range of working conditions, including:
1. High-pressure applications: Plug valves are designed to withstand high-pressure applications, making them suitable for use in pipelines and systems that operate at high pressures, Ball Valve Factory.
2. High-temperature applications: Plug valves can also withstand high temperatures, making them suitable for use in systems that operate at high temperatures.
3. Abrasive media: Plug valves are resistant to wear and can handle abrasive media, making them suitable for use in applications where the media may contain particles or other abrasive materials.
4. Corrosive media: Plug valves are resistant to corrosion and can handle corrosive media, making them suitable for use in applications where the media may be corrosive, Gate Valve Wholesale.
5. Viscous media: Plug valves can handle viscous media, making them suitable for use in applications where the media may be thick or sticky.
6. Slurry applications: Plug valves are also suitable for use in slurry applications, where the media may contain a mixture of solids and liquids.
Overall, plug valves are a versatile valve type that can be used in a wide range of working conditions, making them a popular choice in many industries.
Yes, there are directional restrictions when installing a plug valve. Plug valves are designed to be installed in a specific orientation to ensure proper operation and prevent damage to the valve, Bronze Valve Supplier.
The direction of flow through the valve should be indicated by an arrow on the valve body or handle. The valve should be installed so that the arrow points in the direction of flow. Installing the valve in the wrong direction can cause the plug to become stuck or damage the valve.
In addition to the flow direction, plug valves may also have specific installation requirements based on the type of valve and the application. It is important to follow the manufacturer's instructions and any applicable industry standards when installing plug valves to ensure they are installed correctly and operate safely and efficiently, Check Valve Factory.
Proper maintenance of plug valves is essential to ensure their long-term performance and reliability. Here are some general maintenance tips for plug valves:
1. Regular inspection: Regularly inspect the valve body, plug, stem, and other components for signs of wear, damage, or corrosion. Replace any damaged or worn parts as needed, Wholesale Globe Valve.
2. Lubrication: Lubricate the valve stem and plug with a suitable lubricant to ensure smooth operation. The frequency of lubrication will depend on the application and operating conditions.
3. Cleaning: Clean the valve body and plug regularly to remove any debris or buildup that may affect the valve's performance. Use a suitable cleaning solution and follow the manufacturer's instructions.
4. Operating conditions: Ensure that the valve is operated within its specified temperature and pressure range. Avoid over-tightening the valve, as this can damage the plug and stem.
5. Storage: If the valve is not in use, store it in a dry, clean location to prevent corrosion and damage, Butterfly Valve Factory.
6. Professional maintenance: For more complex maintenance tasks, such as disassembly and reassembly of the valve, it is recommended to seek the assistance of a professional valve technician.
By following these maintenance tips, plug valves can provide reliable and efficient service for many years.
To open and close a plug valve, follow these steps:
1. Determine the valve position: Before operating the valve, make sure you know the valve's position. If the valve is equipped with a handle, the handle will indicate the valve's position. If the valve is equipped with a gear operator, the position can be determined by the position of the gear.
2. Open the valve: To open the valve, turn the handle or gear in a counterclockwise direction. This will rotate the plug inside the valve body, allowing fluid to flow through the valve, Plug Valve Factory.
3. Close the valve: To close the valve, turn the handle or gear in a clockwise direction. This will rotate the plug inside the valve body, stopping the flow of fluid through the valve.
4. Check the valve position: After opening or closing the valve, check the valve position to ensure it is in the correct position. If the valve is not in the correct position, it may not operate properly.
It is important to note that the amount of force required to operate a plug valve can vary depending on the size and type of valve. Always follow the manufacturer's instructions and use the appropriate tools and equipment to operate the valve safely and efficiently.
Send us a message if you have any questions or request a quote.
A reply from our experts within 24 hours
The latest detailed product catalugue
One-stop service for your project