...

This website requires cookies to provide all of it's features. Please enable your browser cookies.

High Temperature Check Valve

High Temperature Check Valve

1、You are in restricted area and need password. Please Contact us to obtain documents.

2、PasswordIf you have any questions about quotation or cooperation, please feel free to send us inquiry. Inquiry us

Brochure:
Manual: Download
3D step: Download
Certificates: Download
Quote
1.Specification
Size: 2"-36"
Pressure: 150LB-2500LB
Body Material: WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, Monel, 20# Alloys, 4A, 5A, C95800, C95500, etc.
Seal Material: STELLITE, 13Cr, SS304, SS316, etc.
Connection Type: Flanged, Butt Welded, Socket Welded, NPT
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Butt Welded Dimension: ASME B16.25
Design and Manufacture: BS1868,API 6D
Test Standard: API 598,API 6FA, ISO 15848-1-2
2.Features

Designed for operating temperatures up to 1103℉(595℃)

Applicable for high temperature working conditions by choosing high temperature resistance material

Less pressure drop, faster closure feature

The disc can be single type or double type.

Unidirectional, without backlash problems, open and close without external manual control

3.FAQ
Is a check valve a backflow preventer

Yes, a check valve is a type of backflow preventer. Its primary function is to prevent the reverse flow or backflow of fluid in a piping system. When the fluid flow direction changes, the check valve automatically closes to prevent the backflow from occurring. This helps to maintain the integrity and safety of the system by preventing contamination, damage, or interference with the normal flow direction. Therefore, check valves are commonly used as backflow preventers in various applications, including water supply systems, irrigation systems, and industrial processes. api 6d ball valve

How often to replace sump pump check valve

The frequency of replacing a sump pump check valve can vary depending on several factors, including the quality of the valve, the operating conditions, and the maintenance practices. In general, it is recommended to inspect the check valve regularly and replace it if any signs of wear or damage are detected.

A well-maintained check valve can last for several years, but it is important to monitor its condition to ensure proper functioning. Signs that may indicate the need for replacement include leaks, excessive noise, reduced flow, or difficulty in operation. forged ball valve

Additionally, it is advisable to replace the check valve if it is not functioning properly or if it is causing issues with the sump pump system. This can help prevent backflow and ensure the efficient operation of the pump.

Consulting the manufacturer's guidelines and recommendations can provide more specific information on the expected lifespan and replacement intervals for a particular sump pump check valve model. It is also recommended to consult with a professional plumber or sump pump specialist for guidance on maintenance and replacement schedules based on your specific system and usage. carbon steel gate valves

How to test a check valve

To test a check valve, you can follow these general steps:

1. Ensure safety: Before testing the check valve, make sure to turn off any power sources and isolate the valve from the system to prevent any accidents or damage.

2. Visual inspection: Inspect the check valve for any visible signs of damage, such as cracks, leaks, or corrosion. If any issues are found, it may be necessary to replace the valve before testing. high temperature gate valves

3. Flow direction: Identify the flow direction indicated on the valve body. Check valves are designed to allow flow in one direction and prevent backflow in the opposite direction. Ensure that the valve is installed correctly with the flow direction aligned.

4. Pressure test: Apply pressure to the system upstream of the check valve. This can be done using a pressure gauge or by opening a valve to allow water or air to flow into the system. Observe the check valve to ensure that it closes properly and prevents backflow.

5. Reverse flow test: Apply pressure to the system downstream of the check valve. This can be done by closing the valve upstream of the check valve and opening a valve downstream. Observe the check valve to ensure that it opens properly and allows flow in the desired direction.

6. Leakage test: After performing the pressure and reverse flow tests, inspect the check valve for any signs of leakage. This can include visible leaks or abnormal sounds. If any leaks are detected, it may be necessary to repair or replace the check valve.

It is important to consult the manufacturer's instructions and guidelines for specific testing procedures and recommended pressure limits for the check valve being tested. Additionally, if you are unsure or uncomfortable performing the test yourself, it is recommended to consult with a professional plumber or valve specialist for assistance, low temperature ball valves.

What is swing check valve

A swing check valve is a type of check valve that is designed to allow fluid to flow in one direction while preventing backflow in the opposite direction. It consists of a disc or flap that swings on a hinge or pivot, allowing fluid to flow through the valve in one direction and closing to prevent backflow.

Swing check valves are commonly used in applications where backflow prevention is critical, such as in water and wastewater treatment plants, industrial processes, and plumbing systems. They are available in a variety of materials, including brass, stainless steel, and PVC, and can be designed to handle a range of pressures and temperatures, api602 forged gate valve.

One advantage of swing check valves is that they have a low pressure drop, meaning that they do not significantly impede the flow of fluid through the system. However, they may be more prone to wear and damage than other types of check valves, particularly if they are exposed to high flow rates or abrasive fluids.

Overall, swing check valves are a reliable and effective solution for preventing backflow in a variety of applications.

Are swing check valves repairable

Yes, swing check valves are generally repairable. The specific repair process will depend on the type of swing check valve and the extent of the damage or wear.

In some cases, the valve may simply need to be cleaned or lubricated to restore proper function. In other cases, the valve may need to be disassembled and repaired or replaced.

Swing check valves are typically designed with replaceable parts, such as the disc or hinge, which can be replaced if they become damaged or worn. However, it is important to ensure that replacement parts are compatible with the specific valve model and are installed correctly to ensure proper function.

Overall, while swing check valves are generally repairable, it is important to follow proper repair procedures and use compatible replacement parts to ensure reliable and safe operation.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details

Related Products

×

Contact Us To Download File

Get in Touch

×