...

This website requires cookies to provide all of it's features. Please enable your browser cookies.

Flanged End Forged Gate Valve

Flanged End Forged Gate Valve

1、You are in restricted area and need password. Please Contact us to obtain documents.

2、PasswordIf you have any questions about quotation or cooperation, please feel free to send us inquiry. Inquiry us

Brochure:
Manual: Download
3D step: Download
Certificates: Download
Quote
1.Specification
Size: 1/2"-2"
Pressure: 150LB-2500LB
Body Material: A105, F304, F304L, F316, F316L, LF1, LF2, LF3, LF9, F51, F53, F11, F22, etc.
Seal Material: STELLITE, 13Cr, SS304, SS316, etc.
Connection Type: Flanged
Operation: Handwheel, gear operated, pneumatic, motorized
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Butt Welded Dimension: ASME B16.25
Design and Manufacture: API 602
Test Standard: API 598, API 624, API 6FA, ISO 15848-1-2
2.Features

Approved by standard API 602, design and manufacture are conform to API 602 standard

Flange ends can be raised face( RF), flat face( FF), ring joint face( RTJ), etc.

Compact structure, easy installation, small torque

Small fluid resistance; high sealing performance

The sealing surface is slightly eroded by media when fully open

Available with bolted bonnet, welded bonnet, and pressure seal bonnet

By choosing different materials, it can be applied to water, steam, oil, nitric acid, acetic acid, oxidizing medium, urea and other media.

Applied to urban construction, chemical industry, metallurgy, petroleum, pharmaceutical, food, beverage, environmental protection, etc.

3.FAQ
Can Gate Valves Be Installed Upside Down?

Gate valves are designed to be installed in a specific orientation and should not be installed upside down. The valve body and the position of the disc or wedge inside the valve are designed to ensure that the valve operates correctly and provides proper sealing. If a gate valve is installed upside down, the disc or wedge may not be able to seal properly against the valve seat, which can cause leaks and other issues.         Additionally, the stem and stem packing may not be properly lubricated or may not be able to function correctly, which can also affect the valve's performance. It is important to carefully follow the manufacturer's installation instructions when installing any valve, including a gate valve, ball valve manufacture.

Can You Just Replace The Knob On a Gate Valve?

Yes, it is possible to replace the knob on a gate valve. Gate valves have a threaded stem that connects the valve's internal gate to the external knob or handle. If the knob is damaged, it can be unscrewed from the stem and replaced with a new one, gate valve manufacture.

Do Gate Valves Have Their Own Id Number?

Yes, gate valves typically have their own identification (ID) number. This ID number is used to track and identify the valve throughout its lifespan, from manufacturing and installation to maintenance and repair, bronze valve.
The ID number may be stamped on the valve body or tag, or it may be provided on a separate identification plate that is attached to the valve. The ID number may include information such as the manufacturer, the model or series of the valve, the size, the pressure rating, and any other relevant information about the valve.
Having a unique ID number for each valve is important for ensuring proper tracking and maintenance of the valve over time. This can help to ensure that the valve is inspected and maintained regularly, and that any necessary repairs or replacements are completed in a timely manner. Additionally, having an ID number for each valve can make it easier to quickly locate and identify the valve in the event of an emergency or outage, api 6d ball valve.

How to Replace Oxidized Gate Valve?

Replacing an oxidized gate valve requires a few steps to be followed carefully. Here is a general guideline for replacing an oxidized gate valve:
1.Shut off the water supply: Locate the main valve and turn it off to cut off the water supply. This will ensure that there is no water flowing through the valve during the replacement process, forged ball valve.
2.Drain the water: Open a faucet downstream of the valve to allow the water to drain out. This will help to reduce the amount of water left in the pipes and make it easier to work on the valve.
3.Remove the old valve: Use a pipe wrench or a similar tool to unscrew the valve from the pipeline. Be careful not to damage the pipe threads while doing this.
4.Clean the pipeline: Use a wire brush or sandpaper to clean the threads of the pipeline. Make sure that there is no debris or rust left on the threads.
5.Install the new valve: Apply Teflon tape or pipe thread sealant to the threads of the pipeline and then screw the new valve onto the pipeline. Tighten the valve with a pipe wrench to ensure that it is secure.
6.Turn on the water supply: Turn on the main valve to restore the water supply. Check the new valve for any leaks and ensure that it is working correctly, carbon steel gate valves.
It is essential to follow proper safety procedures while replacing a gate valve.

Where to Add Gate Valve On a Sprinkler System?

Gate valves are typically used in sprinkler systems to control the flow of water to different areas of the system. They can be installed in various locations depending on the design and layout of the system. Here are some common locations where gate valves can be added to a sprinkler system:
1.Main water supply line: A gate valve can be installed on the main water supply line of the sprinkler system to control the flow of water into the system. This valve is usually installed before the backflow preventer, high temperature gate valves.
2.Zone control valve assembly: Each zone of a sprinkler system typically has its own control valve assembly, which includes a gate valve. These valves are used to turn on and off the water supply to each zone of the system.
3.Water supply riser: A gate valve can be installed on the water supply riser that connects the control valve assembly to the main water supply line. This valve can be used to isolate the control valve assembly for maintenance or repair.
4.Sprinkler head branch line: A gate valve can be installed on the branch line that supplies water to a group of sprinkler heads. This valve can be used to control the flow of water to that particular area of the system.
It is important to note that the installation of gate valves in a sprinkler system should be done by a licensed professional with the proper training and certifications. They can help you determine the best locations for gate valves based on the design and layout of your system.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details

Related Products

×

Contact Us To Download File

Get in Touch

×