This website requires cookies to provide all of it's features. Please enable your browser cookies.

Cast Steel Ball Valve

Cast Steel Ball Valve

1、You are in restricted area and need password. Please Contact us to obtain documents.

2、PasswordIf you have any questions about quotation or cooperation, please feel free to send us inquiry. Inquiry us

Brochure:
Manual: Download
3D step: Download
Certificates: Download
Quote
1.Specification
Size: 2"-56"
Pressure: 150LB-2500LB
Body Material: WCB, WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, 4A, 5A, etc.
Seal Material: PEEK, RPTFE, PTFE, DEVLON, HNBR, NYLON, AFLAS, STELLITE,etc.
Connection Type: Flanged, Butt Welded, Socket Welded, NPT
Operation: Hand lever, gear operated, pneumatic, motorized
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Butt Welded Dimension: ASME B16.25
Design and Manufacture: API 6D
Test Standard: API 598, API 607, API 6FA, ISO 15848-1-2
2.Features

Material can be carbon steel such as: WCB, WCC; Low temperature steel: LCB, LCC; Stainless steel: CF8, CF8M, CF3, CF3M, CF8C, etc.

Bidirectional: no limitation on the flow direction

Fire safe; anti-static design; anti-blowout stem

NACE compliant can be fulfilled upon request.

Operation: lever, worm, pneumatic actuator, electric actuator, etc.

Compact structure, easy to operate and maintain

Suitable for water, solvent, acid, natural gas and other media

Small fluid resistance; small opening and closing torque

3.FAQ
Where are Ball Valves Used?

Ball valves are used in a wide variety of applications where a durable and reliable shut-off valve is required. Here are some common examples:

Plumbing and water systems: Ball valves are commonly used in plumbing and water systems to control the flow of water. They are often used as main shut-off valves for homes and buildings, as well as for controlling the flow of water to specific fixtures like sinks, toilets, and showers.

Industrial applications: Ball valves are widely used in industrial applications, such as oil and gas pipelines, chemical processing plants, and power generation facilities. They are used to control the flow of various types of fluids and gases, including corrosive and abrasive materials, ball valve manufacture.

HVAC systems: Ball valves are used in heating, ventilation, and air conditioning (HVAC) systems to control the flow of hot or cold water or refrigerant. They are often used in large commercial and industrial HVAC systems to regulate the temperature of large spaces.

Fire protection systems: Ball valves are used in fire protection systems to control the flow of water or other extinguishing agents to sprinklers and other fire suppression devices.

Marine and offshore applications: Ball valves are used extensively in marine and offshore applications, such as oil rigs, ships, and submarines. They are used to control the flow of seawater and other fluids, as well as to isolate different sections of the vessel or rig in the event of an emergency, gate valve manufacture.

Overall, ball valves are a versatile and reliable type of valve that can be used in a wide variety of applications where precise control and shut-off capabilities are required, bronze valve.

 

How to use Ball Valve With Drain?

Ball valves with drains are designed to make it easy to drain a plumbing system or a tank without having to disassemble the valve or use other tools. Here's how to use a ball valve with a drain:

Identify the ball valve with the drain: Look for the valve that has a small drain plug or valve at the bottom of the valve body. This is the valve with the drain feature.

Close the valve: Turn the handle or lever of the ball valve to the closed position to stop the flow of water or other fluid through the valve.

Open the drain: Open the small drain plug or valve at the bottom of the valve body by turning it counterclockwise. This will allow any water or fluid that is trapped in the system or tank to drain out, api 6d ball valve.

Drain the system or tank: Once the drain is open, allow the water or fluid to drain out completely. Depending on the size of the system or tank, this may take several minutes.

Close the drain: Once the system or tank is drained, close the drain plug or valve by turning it clockwise until it is snug.

Open the valve: Finally, turn the handle or lever of the ball valve to the open position to allow water or fluid to flow through the valve again.

That's it! With these steps, you can use a ball valve with a drain to drain a plumbing system or a tank quickly and easily, forged ball valve.

 

Can Ball Valve Leaks When Closed?

In theory, a ball valve should not leak when it is fully closed. When the valve is closed, the ball inside the valve is pressed against the valve seat, creating a tight seal that prevents the flow of fluid through the valve.

However, in practice, there are some situations where a ball valve can leak even when it is fully closed. Some possible causes of leakage include:

Damage to the valve: If the valve or its components are damaged, such as the ball or the seat, it may not create a proper seal when the valve is closed, carbon steel gate valves.

Improper installation: If the valve is not installed correctly or the pipes are not properly aligned, it can create stress on the valve, which may cause it to leak.

Corrosion: Over time, corrosion can build up on the valve, which can prevent it from closing fully and create a leak.

High pressure or temperature: If the valve is subjected to high pressure or temperature, it can cause the components to expand, which may prevent the valve from closing fully and lead to a leak.

In order to prevent leaks from a ball valve, it is important to ensure that the valve is properly installed and maintained. This includes regular inspection and cleaning of the valve, as well as checking for any signs of damage or wear. If a leak is detected, it should be addressed immediately to prevent any further damage or safety hazards.

 

Do Ball Valves Have Packing?

Yes, some ball valves have packing, which is a material used to create a seal between the valve stem and the valve body. The packing material is typically a compressible material, such as PTFE (polytetrafluoroethylene) or graphite, that is wrapped around the valve stem and compressed against the valve body to create a seal.

The purpose of the packing is to prevent leaks around the valve stem, which can occur if there is a gap between the stem and the valve body. Over time, the packing material can wear out or become damaged, which can cause leaks to occur. When this happens, the packing material needs to be replaced.

Some ball valves are designed with a "live loaded" packing system, which uses a spring to apply constant pressure to the packing material. This helps to ensure a tight seal and can extend the life of the packing material, high temperature gate valves.

In summary, while not all ball valves have packing, some do, and it is an important component of the valve that helps to prevent leaks around the valve stem.

Regenerate response

 

How to Fit a Lever Ball Valve?

Fitting a lever ball valve involves several steps, but the process is relatively straightforward. Here's a general overview of the steps involved:

Choose the right valve: Before you begin, make sure you have the right lever ball valve for your application. Consider factors such as the size and type of pipe, the pressure and temperature of the fluid, and the specific requirements of your system.

Turn off the supply: Shut off the supply of fluid to the area where you'll be installing the valve. This will help to prevent leaks and ensure your safety during the installation process.

Prepare the pipe: Use a pipe cutter or saw to cut the pipe where you want to install the valve. Make sure the ends of the pipe are clean and free of debris.

Apply Teflon tape: Wrap a few layers of Teflon tape around the threads on both ends of the valve. This will help to create a tight seal when you attach the valve to the pipe.

Attach the valve: Screw the valve onto the pipe by hand, making sure the threads are aligned properly. Use a wrench to tighten the valve securely.

Test the valve: Turn the valve to the open position and turn the supply back on. Check for any leaks or other issues. If everything looks good, turn the valve to the closed position and turn the supply off again.

Make any necessary adjustments: If you notice any leaks or other issues, you may need to adjust the valve or tighten the connections further.

Secure the valve: Once everything is working properly, secure the valve in place using clamps or other fittings as necessary.

These are general guidelines for fitting a lever ball valve. It's important to consult the manufacturer's instructions and follow all relevant safety guidelines when installing any type of valve. If you're unsure about any aspect of the installation process, it's best to consult a professional plumber or other expert.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details

Related Products

×

Contact Us To Download File

Get in Touch

×