Size: | 2"-36" |
Pressure: | 150LB-2500LB |
Body Material: | WCB, WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, Monel, 20# Alloys, 4A, 5A, C95800, C95500, A105, F304, F304L, F316, F316L, LF1, LF2, LF3, LF9, F51, F53, F11, F22, etc. |
Seal Material: | STELLITE, 13Cr, SS304, SS316, etc. |
Connection Type: | Flanged, Butt Welded, Socket Welded, NPT |
Face to Face Dimension: | ASME B16.10 |
Flange End Dimension: | ASME B16.5 |
Butt Welded Dimension: | ASME B16.25 |
Design and Manufacture: | API 6D |
Test Standard: | API 598,API 6FA, ISO 15848-1-2 |
Flexible opening and closing, high sealing performance
Long service life and high reliability
Smooth flow path, small fluid resistance with fully open flow channel
Applicable media: water, oil, steam, etc.
Yes, check valves can be installed horizontally. Horizontal installation is a common practice in various piping systems. Check valves are designed to function effectively in both horizontal and vertical orientations. When installing horizontally, ensure that the valve is properly sized for your specific flow rates, aligned with the directional indicator in the direction of flow, well-supported to minimize stress on the valve and piping, and located for easy access for maintenance or repair when necessary. Proper installation, adherence to manufacturer guidelines, and consideration of system-specific requirements are essential to ensure the check valve's effective operation in a horizontal position. api 6d ball valve
A spring check valve, also known as a check valve or non-return valve, is a type of one-way valve used in various fluid systems to ensure the flow of a fluid occurs in only one direction. It consists of a valve body with an internal passage and a hinged or spring-loaded flap or disc. The spring check valve is designed to allow fluid to flow in the forward direction while preventing backflow. forged ball valve
The valve operates as follows: When fluid flows in the desired direction, the pressure lifts the disc, allowing the fluid to pass through. However, when there is a reversal of flow or a decrease in pressure, the spring or gravity forces the disc to close, blocking the reverse flow and preventing backflow. Spring check valves are widely used in plumbing, industrial, and hydraulic systems to maintain flow control, prevent contamination, and ensure the efficient operation of piping and machinery. carbon steel gate valves
A vacuum check valve, also known as a one-way check valve, is a component used in vacuum systems to control the direction of airflow. It allows air or gas to flow in one direction while preventing it from flowing in the opposite direction. Vacuum check valves are crucial for maintaining proper vacuum levels, preventing contamination, and ensuring the integrity of vacuum systems.
In a vacuum system, these valves typically consist of a housing with an internal passage and a one-way valve mechanism, such as a flap or a spring-loaded diaphragm. When the vacuum source is active, the valve opens to allow air or gas to be drawn into the system. However, when the vacuum source is turned off or the pressure differential changes, the valve closes to prevent air from flowing back into the vacuum system, maintaining the desired vacuum level and system efficiency. high temperature gate valves Vacuum check valves find applications in various industries, including automotive, medical, and manufacturing.
Fixing a leaking check valve depends on the type of valve and the extent of the issue:
1.Inspect the Valve: First, turn off the flow to the valve. Examine the valve for visible damage, corrosion, or debris that might be causing the leak.
2.Tighten Connections: If the leak is at a threaded connection, try tightening it gently with a wrench or pliers, low temperature ball valves.
3.Clean or Replace Seals: If the leak persists, consider disassembling the valve to inspect and clean or replace the sealing components like O-rings, gaskets, or flapper discs. Make sure to use compatible replacement parts.
4.Check for Debris: Sometimes, foreign debris can prevent proper sealing. Clean the valve thoroughly and inspect for any obstructions.
5.Professional Help: If the leak continues, or the valve is significantly damaged, it may need replacement. Consult a professional to assess the issue and replace the valve if necessary.
Remember to follow safety guidelines and turn off the flow before attempting any repair. If you are unsure about the repair process, it's always a good idea to seek professional assistance, api602 forged gate valve.
The internal structure of a check valve can vary depending on its type and design, but here's a generalized description of the inside of a typical swing check valve, one of the common types:
1.Body: The valve body is a cylindrical or tubular structure with inlet and outlet ports. It houses the internal components.
2.Swing Disc/Flapper: Inside the body, there is a hinged or swing disc (also known as a flapper) that acts as the valve's one-way door. When there is forward flow, the disc swings open to allow fluid to pass through. In reverse flow or when the flow stops, the disc swings closed to prevent backflow.
3.Hinge/Pivot: The disc is attached to a hinge or pivot point within the body, allowing it to swing freely.
4.Seat: The valve body has a seating surface against which the disc closes to form a tight seal when preventing backflow.
5.Spring (in some designs): Some check valves include a spring to assist the disc in closing quickly, which can reduce the chances of water hammer.
The specific design may vary based on the type of check valve and its intended application.
Send us a message if you have any questions or request a quote.
A reply from our experts within 24 hours
The latest detailed product catalugue
One-stop service for your project