This website requires cookies to provide all of it's features. Please enable your browser cookies.

Views:36
Share:

Spiral Wound Gasket

The spiral wound gasket has high compression and resilience performance, with multi-channel sealing and certain self-tightening function. It is less sensitive to surface defects on the flange pressing surface and does not adhere to the flange sealing surface, which can partially eliminate the influence of pressure and temperature change and mechanical vibration. It can maintain its excellent sealing performance under various harsh conditions such as high temperature, low temperature, high vacuum, vibration, etc.

 

Technical parameters of spiral wound gasket:

Spiral wound gasket coefficient m=2.5-4
Spiral wound gasket operating pressure ≤25MPa
Spiral wound gasket operating temperature -196℃~700℃(not higher than 600℃in oxidizing medium)
Spiral wound gasket minimum pretightening load y=68MPa

 

Material selection of inner ring and metallic spiral wound tape:

Material Abbreviation Hardness(HB) Temperature(℃)
SUS 304 304 130~180 -195~+550
SUS 316L 316L 130~180 -100~+550
SUS 321 321 130~190 -195~+760
HASTELLOR-B2 HASTB 215 -185~+1090
INCONEL-600 INC600 150 -100~+1090
MONEL-400 MON 150 -130~+820
TITANIUM T2 215 -195~+1090

 

Diameter allowance of spiral wound gasket (nominal pipe diameter for flange):

 

DIN (mm)

 

ANSI B16.5
BS1560 (mm)
Mss sp-44
 

API 605

 

Allowance

 

 

Inner ring inner diameter

Gasket inner diameter

<=600 <=24" >=26" and <=34" ±0.5
>600 and <=800 >24" and <=34" >=36" and <=60" ±0.9
>800 and <=1600 >34" and <=60" ±1.3
>1600 >60" ±1.6
 

Gasket outer diameter

<=600 <=24" <=24" ±0.9
>600 and <=160000 >24" and <=60" >24" and <=60" ±1.8
1600 >60" ±2.2
 

 

Outer ring outer diameter

>=1/2" and <=60" ±0.9
<=600 <=24" 0-1.0
>600 and <=1000 >24" and <=34" 0-1.8
>1000 and <=1600 >34" and <=60" 0-2.2